USING A MAGNETIC PULSE GENERATOR
FOR LYMPH & TISSUE ELECTRIFICATION
Based on the research of Robert C. Beck, D.Sc.
CAUTION: As with any electrical unit, do not immerse the unit or coil in water.
Parts List: One (1) Magnetic Pulse Generator unit with Magnetic Coil
               One (1) AC?DC Wall Adapter (12 VDC @ 1.2 Amp Output, Center?positive) One (1) Operating Instructions
Operation of the Unit:

  1. Insert the power plug from the AC?DC Wall adapter into the Magnetic Pulse Generator.
  2. Some units have an automatic feature: When turned on, the Green LED bar graph lights come on sequentially. When the Magnetic Pulse Generator reaches full charge the last of 'the Green LED lights will light up. The unit now automatically triggers & releases the charge to the Magnetic Coil. After the pulse has been delivered, the unit will immediately begin to re?charge. This automatic charging/discharging cycle will take 3.5 seconds.

    Timer: An internal digital counter will track the number of pulses delivered. After about 5?10 minutes use, the Red LED light Will come on and?the unit will stop pulsing and go into standby mode. To reset, Generator off momentarily then back on again.

    IMPORTANT: If at any time the Red LED light comes on other than after using for about 5–10 minutes, this indicates trouble. Turn the unit OFF then back ON. If the condition persists, contact the manufacturer for warranty repair.
  3. Use the magnetic Bio?North (–) pole as indicated on the coil (May be a Hand–Paddle) towards the affected area. Each time the last Green LED light illuminates, a pulse is sent to the coil. The Bio–North (–) magnetic pole should be clearly indicated and correctly defined as the South–seeking pole.
  4. If the unit is being used for extended sessions, allow the unit to cool for a few minutes between resets. If the coil is encased in a paddle, it will become very warm with extended use. This is normal. Allow it to cool before continuing.
  5. For overall use, move the coil or Hand Paddle every few pulses to a new position. Use for appioximately 20 minutes per session. You can pulse a specific site as well as an overall protocol.
  6. Turn the unit off and unplug the wall adapter when not in use.
WARNING: Always operate the unit on a hard, flat surface so the vent holes are not impeded.
NOTE: It's important to drink at least six to eight glasses of water a day while using this unit.
CAUTION: As with any electrical unit, do not immerse the unit or coil in water.
CAUTION: The Magnetic Pulse Generator generates an intense magnetic field. Keep away from homeopathic remedies, credit cards, security cards, audio and video tapes, computer discs, other computer storage media, answering machines, or any other sensitive electronic equipment that may be damaged by magnetic fields.

As with any electrical unit: Do not use with a heart pacemaker * Do not use on pregnant women * Do not use while driving * Do not use while operating hazardous machinery.
TO TEST A MAGNETIC PULSE GENERATOR
A Magnetic, Pulse Generator generates a powerful magnetic field that, of course, cannot be felt, seen or heard. To test for the presence of the magnetic field, place a heavy metal object such as a spoon on the coil or Hand–Paddle. With each pulse that is released the object will jump or move off the coil.
There are two methods to test the intensity or extent of magnetic penetration:
  1. Bring a compass within one,foot of the pulsed field and slowly move closer until the compass needle is attracted. Do not bring too close as the pulsed magnetic field can de–magnetize the compass. Each pulse should penetrate 9 inches.
  2. For precise measurement, you can purchase a Mag–Probe, Model HS from:
Bartol Research
PO Box 190881
Boise, ID 83719
Phone:208–321–7566
Fax:208–378–1282
When pulsed the magnetic field should light up the bulb of the Mag–Probe from a distance of 9 inches.
Note: The Mag–Probe can also determine polarity but the manufacturer of the Mag–Probe confirms that the polarity for north is not defined as south–seeking. This means it is not in agreement with the polarity indicated on your Magnetic Pulser. The Magnetic Pulser indicates true Bio–North (–), which is South–seeking.
ELECTRICAL SPECIFICATIONS
Power Requirements: 12 VDC @ 1.2 Amps, Centre Positive. May be optionally powered by a 12 Volt DC source like an automotive battery or solar panel. It is necessary to purchase an appropriate adapter with a centre positive output from an electronics store. (Radio Shack #270–1528, tip positive)
Electrical Specifications:
Main Storage Capacitor: 600 uF, 450 VDC
Maximum Energy Storage: 36.75 Joules
(Watt*Secs)
Magnetic Field Intensity: >43,133 Gauss
Typical Peak Charge Voltage: 330 VDC
Maximum Peak Charge Voltage: 350 VDC
Maximum Peak Current into Coil: 150 Amps
Pulse Rise Time: <1.0 uS (microseconds)
Pulse Duration: ~2.5 mS (milliseconds)
Number of Discharge Cycles: 30 million
The Magnetic Pulser is for researchers only.

This unit has not been evaluated by the Food and Drug Administration in the US. In Canada the Magnetic Pulser is licensed to:
1) Improve tissue oxygenation, blood flow and healing. 2. Reduce edema as the result of injury. 3. Relieve chronic pain from osteoarthritis & musculloskelletal injuries. These products are not intended to cure or treat any disease.

Individual results will vary. Government health departments and medical associations state that you must consult a medical doctor for treatment of all diseases.